1SAM250000R1007Fotografía del producto no facilitada

Referencia de catálogo. La disponibilidad, especificación exacta y suministro original o alternativo se confirman en el presupuesto.

ABB

1SAM250000R1007 — Motor protection circuit-breaker

Electricidad y control

Referencia de la pieza: 1SAM250000R1007

ABB MS116-2.5 (1SAM250000R1007) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 1.6–2.5 A overload range. It provides manual switching and protection against overload, short circuit and phase failure. The unit has screw terminals, a rotary handle and a disconnect function. Its rated three-phase AC-3 operational power is 0.75 kW at 400 V.

¿Busca ABB 1SAM250000R1007? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteABB
Referencia de la pieza1SAM250000R1007
CategoríaElectricidad y control
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-2.5 valid for production date from week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 230 V AC; 50 kA at 400 V AC; 10 kA at 440 V AC; 10 kA at 500 V AC; 5 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )75 kA at 230 V AC; 75 kA at 400 V AC; 30 kA at 440 V AC; 20 kA at 500 V AC; 10 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )31.3 A
Setting Range1.6–2.5 A
Rated Operational Power AC-3 (P e )(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )2.5 A
Rated Operational Current AC-3 (I e )2.5 A
Rated Operational Current AC-3e (I e )2.5 A
Rated Frequency (f)Main circuit: 50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 2.5 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail
Actuator TypeRotary handle

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.