1SAM250000R1008Fotografía del producto no facilitada

Referencia de catálogo. La disponibilidad, especificación exacta y suministro original o alternativo se confirman en el presupuesto.

ABB

1SAM250000R1008 — Motor protection circuit-breaker

Electricidad y control

Referencia de la pieza: 1SAM250000R1008

ABB 1SAM250000R1008 is the MS116-4.0 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 2.5–4.0 A overload setting, trip class 10A, screw terminals and a rotary ON/OFF handle. Designed for manual motor switching, it provides overload, short-circuit and phase-failure protection. Its rated service short-circuit breaking capacity is 50 kA at 400 V AC. Confirm motor and circuit requirements before selection.

¿Busca ABB 1SAM250000R1008? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteABB
Referencia de la pieza1SAM250000R1008
CategoríaElectricidad y control
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-4.0
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )230 V AC: 50 kA; 400 V AC: 50 kA; 440 V AC: 6 kA; 500 V AC: 6 kA; 690 V AC: 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )230 V AC: 75 kA; 400 V AC: 75 kA; 440 V AC: 18 kA; 500 V AC: 15 kA; 690 V AC: 3 kA
Rated Instantaneous Short-Circuit Current Setting (I i )50 A
Setting Range2.5–4.0 A
Rated Operational Power AC-3 (P e )400 V, three-phase: 1.5 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 1.5 kW
Rated Operational VoltageMain circuit 690 V AC
Rated Operational Current (I e )4 A
Rated Operational Current AC-3 (I e )4 A
Rated Operational Current AC-3e (I e )4 A
Rated Frequency (f)Main circuit 50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 4 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Extended product typeMS116-4.0
Trip class10A

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.