Ilustración técnica — ABB 1SAM340000R1007 — 1SAM340000R1007 — Power circuit-breaker for trafo/generator/installation protection

Ilustración técnica. Representative component image; exact configuration and appearance may vary. Imágenes solo de referencia. La apariencia de la pieza suministrada puede variar.

ABB

1SAM340000R1007 — Power circuit-breaker for trafo/generator/installation protection

Electricidad y control

Referencia de la pieza: 1SAM340000R1007

ABB MS132-2.5T (1SAM340000R1007) is a three-pole circuit breaker designed for primary-side control transformer protection. It provides adjustable overload protection from 1.6 to 2.5 A, short-circuit protection and manual disconnection. The device has screw terminals and a rotary operating handle. Confirm the transformer and installation requirements before selection.

¿Busca ABB 1SAM340000R1007? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteABB
Referencia de la pieza1SAM340000R1007
CategoríaElectricidad y control
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-2.5T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC and 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )50 A
Setting Range1.6–2.5 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )2.5 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.6 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 2.5 A
Degree of ProtectionHousing: IP20; main circuit terminals: IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.