1SAM350000R1001 — Motor protection circuit-breaker
Electricidad y controlReferencia de la pieza: 1SAM350000R1001
ABB 1SAM350000R1001 is the MS132-0.16 three-pole manual motor starter, with a 0.10–0.16 A adjustable overload setting. It combines manual motor switching with overload, short-circuit and phase-failure protection. The device has a lockable rotary handle, screw terminals and a 45 mm-wide housing.
¿Busca ABB 1SAM350000R1001? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | ABB |
|---|---|
| Referencia de la pieza | 1SAM350000R1001 |
| Categoría | Electricidad y control |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-0.16 valid for production date from week 34/2014 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.215 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (230 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 2 A |
| Setting Range | 0.10–0.16 A |
| Rated Operational Power AC-3 (P e ) | (400 V) Three Phase 0.03 kW |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 0.03 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 0.16 A |
| Rated Operational Current AC-3 (I e ) | 0.16 A |
| Rated Operational Current AC-3e (I e ) | 0.16 A |
| Rated Operational Current DC-5 (I e ) | 0.16 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.7 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 0.16 A |
| Degree of Protection | Housing IP20 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Mounting | Standard DIN rail |