Ilustración técnica — ABB 1SBH137001R1422 — 1SBH137001R1422 — Block Contactor Relay

Ilustración técnica. Representative component image; exact configuration and appearance may vary. Imágenes solo de referencia. La apariencia de la pieza suministrada puede variar.

ABB

1SBH137001R1422 — Block Contactor Relay

contactor

Referencia de la pieza: 1SBH137001R1422

ABB 1SBH137001R1422 is an NF22E-14 four-pole contactor relay for auxiliary and control circuits. It has two normally open and two normally closed mechanically linked contacts, a 250–500 V AC 50/60 Hz or DC electronic control coil, built-in surge protection and screw terminals.

¿Busca ABB 1SBH137001R1422? Esta referencia de catálogo está clasificada como «contactor». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteABB
Referencia de la pieza1SBH137001R1422
CategoríaElectricidad y control
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I e )6 A at 24–127 V; 4 A at 220–240 V; 3 A at 400–440 V; 2 A at 500 V; 2 A at 690 V
Rated Operational Current DC-13 (I e )6 A / 144 W at 24 V DC; 2.8 A / 134 W at 48 V DC; 1 A / 72 W at 72 V DC; 0.55 A / 60 W at 110 V DC; 0.55 A / 69 W at 125 V DC; 0.27 A / 60 W at 220 V DC; 0.27 A / 68 W at 250 V DC; 0.15 A / 60 W at 400 V DC; 0.13 A / 65 W at 500 V DC; 0.1 A / 60 W at 600 V DC
Rated Short-time Withstand Current Low Voltage (I cw )for 0.1 s 140 A
Rated Insulation Voltage (U i )acc. to IEC 60947-5-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Maximum Electrical Switching FrequencyAC-15: 1,200 cycles per hour; DC-13: 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (U c )250–500 V AC, 50/60 Hz; 250–500 V DC
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Mounting on DIN RailTH35-7.5 (35 × 7.5 mm) or TH35-15 (35 × 15 mm), according to IEC 60715
Mounting by Screws (not supplied)2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Published component typeBlock Contactor Relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Surge ProtectionBuilt-in coil surge protection
Contact Configuration2 normally open and 2 normally closed mechanically linked auxiliary contacts
Ambient Operating Temperature−40 to +70 °C in free air near the contactor

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.