Ilustración técnica. Representative component image; exact configuration and appearance may vary. Imágenes solo de referencia. La apariencia de la pieza suministrada puede variar.
1SBL407001R1300 — Block Contactor
contactorReferencia de la pieza: 1SBL407001R1300
1SBL407001R1300 — Block Contactor — ABB reference 1SBL407001R1300. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
¿Busca ABB 1SBL407001R1300? Esta referencia de catálogo está clasificada como «contactor». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | ABB |
|---|---|
| Referencia de la pieza | 1SBL407001R1300 |
| Categoría | Electricidad y control |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 116 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 1.17 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 130 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 60 °C 96 A |
| Rated Operational Current AC-3e (I e ) | (415 V) 60 °C 96 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 2 Poles in Series, 40 °C 130 A |
| Show more Rated Operational Current DC-3 (I e ) | (110 V) 2 Poles in Series, 40 °C 130 A |
| Show more Rated Operational Current DC-5 (I e ) | (110 V) 2 Poles in Series, 40 °C 130 A |
| Show more Rated Operational Power AC-3 (P e ) | (415 V) 55 kW |
| Rated Operational Power AC-3e (P e ) | (415 V) 55 kW |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 1000 V |
| Rated Impulse Withstand Voltage (U imp ) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 50 Hz 100 ... 250 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 8.2 W |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.