1SFL427102R1311 — Block Contactor
contactorReferencia de la pieza: 1SFL427102R1311
1SFL427102R1311 — Block Contactor — ABB reference 1SFL427102R1311. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
¿Busca ABB 1SFL427102R1311? Esta referencia de catálogo está clasificada como «contactor». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | ABB |
|---|---|
| Referencia de la pieza | 1SFL427102R1311 |
| Categoría | Electricidad y control |
| Product Net Width | 120 mm |
| Product Net Depth / Length | 128 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.95 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 160 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 55 °C 116 A |
| Rated Operational Power AC-3 (P e ) | (415 V) 55 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | 50 Hz 100 ... 250 V |
| Power Loss | at Rated Operating Conditions per Pole 12 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 40 ... 70 ms |
| Connecting Capacity Main Circuit | Flexible 1 x 10 ... 70 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.