1SFL647001R6811 — Block Contactor
contactorReferencia de la pieza: 1SFL647001R6811
1SFL647001R6811 — Block Contactor — ABB reference 1SFL647001R6811. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
¿Busca ABB 1SFL647001R6811? Esta referencia de catálogo está clasificada como «contactor». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | ABB |
|---|---|
| Referencia de la pieza | 1SFL647001R6811 |
| Categoría | Electricidad y control |
| Product Net Width | 210 mm |
| Product Net Depth / Length | 242 mm |
| Product Net Height | 344 mm |
| Product Net Weight | 14.6 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
| Rated Operational Current AC-1 (I e ) | (1000 V) 40 °C 1260 A |
| Rated Operational Current DC-1 (I e ) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Operational Current DC-3 (I e ) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Operational Current DC-5 (I e ) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | DC Operation 24 ... 60 V |
| Power Loss | at Rated Operating Conditions per Pole 80 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 50 ... 70 ms |
| Connecting Capacity Main Circuit | Bar 50 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |