Ilustración técnica — ABB 2CSA275103R1204 — 2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Ilustración técnica. Published product/series reference; confirm the exact configuration and supplied appearance. Imágenes solo de referencia. La apariencia de la pieza suministrada puede variar.

ABB

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Electricidad y control

Referencia de la pieza: 2CSA275103R1204

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device — ABB reference 2CSA275103R1204. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

¿Busca ABB 2CSA275103R1204? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteABB
Referencia de la pieza2CSA275103R1204
CategoríaElectricidad y control
Type of Residual CurrentType A
Test Voltage (Ut)170 … 264 V
Dielectric Test Voltage2.5 kV
Rated Ultimate Short-Circuit Breaking Capacity (I cu )10 kA
Rated Residual Breaking Capacity (IΔm)6 kA
Rated Service Short-Circuit Breaking Capacity (I cs )7.5 kA
Power Supply ConnectionArbitrary
Number of Protected Poles1
Number of Poles1P+N
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Mounting Position of AccessoriesRight
Connecting CapacityBusbar 10 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Rated Operational Voltage230...240 V AC
Rated Insulation Voltage (U i )500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Input Voltage TypeAC
Rated Current (I n )20 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity10 kA
Rated Frequency (f)50 … 60 Hz
Power Loss4.2 W
Overvoltage CategoryIII
Ambient Air TemperatureOperation -25 ... 55 °C
Published component typeEarth leakage circuit breaker with auxiliary device
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.