2CSF204568R3400 — Residual current circuit breaker (RCCB) — ABB reference 2CSF204568R3400. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
¿Busca ABB 2CSF204568R3400? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | ABB |
|---|---|
| Referencia de la pieza | 2CSF204568R3400 |
| Categoría | Electricidad y control |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 29 % |
| Type of Residual Current | Type B |
| Test Voltage (Ut) | 110 ... 253 V |
| Dielectric Test Voltage | 2500 kV |
| Impulse Current | I (max, 8 / 20 µs) 3000 A |
| Maximum Surge Current | 3 kA |
| Leakage Current Type | B |
| Number of Poles | 4P |
| Operating Characteristic | 10ms Delay (High Immunity) |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Connecting Capacity | Busbar 10 mm² |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Rated Voltage (U r ) | 230/400 V |
| Rated Operational Voltage | 230 … 400 V AC |
| Rated Insulation Voltage (U i ) | 440 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (I n ) | 40 A |
| Rated Residual Current | 300 mA |
| Rated Conditional Short-Circuit Current (I nc ) | (Typ gG/gLfuse, 500 V) 100 A |
| Frequency ( f ) | 50/60 Hz |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | at Rated Operating Conditions per Pole 1.92 W |
| Overvoltage Category | III |
| Ambient Air Temperature | Operation -25...+65 °C |
| Published component type | Residual current circuit breaker (RCCB) |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |