A9C15915 — This Acti 9 iACTs is reliable remote indication auxiliary. It has 1 changeover contact, it operates from 24VAC to 240VAC and 24VDC to 130VDC. Mounting is performed on the right…
Gestión de cables y transferencia de energíaReferencia de la pieza: A9C15915
A9C15915 — This Acti 9 iACTs is reliable remote indication auxiliary. It has 1 changeover contact, it operates from 24VAC to 240VAC and 24VDC to 130VDC. Mounting is performed on the right… — Schneider Electric reference A9C15915. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
¿Busca Schneider Electric A9C15915? Esta referencia de catálogo está clasificada como «Gestión de cables y transferencia de energía». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.
Disponibilidad bajo consulta
Especificaciones técnicas
| Fabricante | Schneider Electric |
|---|---|
| Referencia de la pieza | A9C15915 |
| Categoría | Gestión de cables y transferencia de energía |
| Range of product | ICT |
| Range | Acti9 |
| Product or component type | Remote indication auxiliary |
| Signal contacts composition | 1 C/O |
| Signalling circuit voltage | 24 V AC/DC: 10 mA 230 V AC: 50/60 Hz 5 A 230 V AC: 50/60 Hz 2 A 130 V DC: 1 A |
| [Uc] control circuit voltage | 24...240 V AC 50/60 Hz 24...130 V DC |
| Range compatibility | Acti9 iCT |
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Mounting mode | Fixed, on the right of CT |
| Mounting support | 35 mm symmetrical DIN rail |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 68 mm |
| Auxiliary connection terminal | Tunnel type terminals 2 cable(s) flexible 2.5 mm² Tunnel type terminals 2 cable(s) rigid 1.5 mm² Tunnel type terminals 1 cable(s) rigid 1.5…2.5 mm² Tunnel type terminals 1 cable(s) flexible 1.5…2.5 mm² |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Reference status | Published part reference; specification and fitment require confirmation |