Imagen de referencia del componente: Published product/series reference; confirm the exact configuration and supplied appearance.

Imagen representativa del tipo de componente, no una foto de esta marca o referencia exacta. Confirme la especificación; la pieza suministrada puede tener otro aspecto.

Schneider Electric

GV4AU027 — TeSys GV electrical trip unit, MN undervoltage release, 24V AC 50/60Hz and 24V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the…

Gestión de cables y transferencia de energía

Referencia de la pieza: GV4AU027

GV4AU027 — TeSys GV electrical trip unit, MN undervoltage release, 24V AC 50/60Hz and 24V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the… — Schneider Electric reference GV4AU027. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

¿Busca Schneider Electric GV4AU027? Esta referencia de catálogo está clasificada como «Gestión de cables y transferencia de energía». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteSchneider Electric
Referencia de la piezaGV4AU027
CategoríaGestión de cables y transferencia de energía
RangeTeSys
Product or Component TypeVoltage release
Range compatibilityTeSys TeSys GV4 TeSys TeSys BV4
Voltage release typeUndervoltage release
[Uc] control circuit voltage24 V AC 50/60 Hz 24 V DC
[Ui] rated insulation voltage24 V IEC 60947-1
Threshold tripping voltage< 0.35 Un failsafe opening 0.35...0.7 Un possible opening 0.85...1.1 Un enabled closing
Mounting ModeInternal mounting
Maximum inrush power in VA7 VA
Maximum inrush power in W2 W
Maximum hold-in power consumption in VA7 VA
Maximum hold-in power consumption in W2 W
Operating time< 50 ms
Connections - terminalsSpring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length0.3 in (8 mm)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.