LV430451 — This TM125D is 4 poles 4d thermal-magnetic trip unit used on Compact NSX 160/250 circuit breakers. This 125A rating thermal-magnetic trip unit is an optimum choice for all…

Electricidad y control

Referencia de la pieza: LV430451

LV430451 — This TM125D is 4 poles 4d thermal-magnetic trip unit used on Compact NSX 160/250 circuit breakers. This 125A rating thermal-magnetic trip unit is an optimum choice for all… — Schneider Electric reference LV430451. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

¿Busca Schneider Electric LV430451? Esta referencia de catálogo está clasificada como «Electricidad y control». Envíe el número de pieza y los datos de su equipo para confirmar las especificaciones y la disponibilidad y preparar un presupuesto con envío incluido.

Disponibilidad bajo consulta

Precio bajo presupuesto

Envío incluidoGarantía y servicioObtener un presupuesto para esta pieza

Especificaciones técnicas

FabricanteSchneider Electric
Referencia de la piezaLV430451
CategoríaElectricidad y control
RangeComPact
Range of ProductComPact NSX100...250
Product or Component TypeTrip unit
Range CompatibilityComPact NSX160 ComPact NSX250
Number of poles4P
Protected poles description4t
Trip unit protection functionsLI
Protection typeL : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rated current125 A 104 °F (40 °C)
[Ue] rated operational voltage690 V AC 50/60 Hz
Network Frequency50/60 Hz
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s 1.5 x In 15 s 6 x Ir
Short-time protection pick-up adjustment type IsdFixed
[Isd] Short-time protection pick-up adjustment range1250 A
Short-time protection delay adjustment type tsdFixed
Earth-leakage protectionWithout
Neutral protection settings1 x Ir 4t)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

La información del catálogo puede contener errores o estar desactualizada. Las especificaciones completas y los datos verificados están disponibles bajo petición. Confirme con nosotros la referencia y la compatibilidad con su equipo antes de realizar el pedido.

Preguntas sobre el producto

La información investigada sobre esta pieza aún no está disponible en español. Consulte a nuestro equipo.

Obtener un presupuesto para esta pieza

Siéntase como en casa.

Elija su idioma y destino de entrega. El precio final y el envío se confirman en su presupuesto.