Illustration technique. Representative component image; exact configuration and appearance may vary. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.
1SAE231111R0630 — Installation Contactor
contacteurRéférence de la pièce: 1SAE231111R0630
ABB 1SAE231111R0630 is the ESB25-30N-06 three-pole installation contactor, with three normally open main contacts and a 230–240 V control circuit. It is rated 25 A in AC-1 and 9 A in AC-3 under the specified operating conditions. Dimensions are 36 × 85 × 65 mm (W × H × D). Confirm the control supply and load requirements before selection.
Vous recherchez ABB 1SAE231111R0630 ? Cette référence de catalogue est classée sous « contacteur ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | ABB |
|---|---|
| Référence de la pièce | 1SAE231111R0630 |
| Catégorie | Électricité et commandes |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.23 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main circuit: 400 V AC; 220 V DC |
| Rated Frequency (f) | Control circuit: 50 Hz, 60 Hz, 400 Hz and DC; main circuit: 50 Hz, 60 Hz and DC |
| Rated Operational Current AC-1 (I e ) | (NO) 25 A |
| Rated Operational Current AC-3 (I e ) | 9 A at 230 V single-phase or 400 V three-phase, normally open |
| Rated Operational Current AC-7a (I e ) | (NO) 25 A |
| Rated Operational Current AC-7b (I e ) | 9 A at 230 V single-phase or 400 V three-phase, normally open |
| Rated Operational Power AC-1 (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-3 (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7a (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7b (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230 ... 240 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Degree of protection | IP20 |
| Ambient air temperature | Operation: -25 to +55 °C; storage: -40 to +80 °C |
Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.
Questions sur le produit
Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.
Obtenir un devis pour cette pièce