Illustration technique — ABB 1SAE341111R0631 — 1SAE341111R0631 — Installation Contactor

Illustration technique. Representative component image; exact configuration and appearance may vary. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.

ABB

1SAE341111R0631 — Installation Contactor

contacteur

Référence de la pièce: 1SAE341111R0631

ABB 1SAE341111R0631 is an ESB40-31N-06 four-pole installation contactor with three normally open and one normally closed main contacts. It has a rated control voltage of 230 V and a listed AC-1 current of 40 A on the normally open contacts. Check the contact arrangement, load category and circuit ratings before selection.

Vous recherchez ABB 1SAE341111R0631 ? Cette référence de catalogue est classée sous « contacteur ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAE341111R0631
CatégorieÉlectricité et commandes
Product Net Width54 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.405 kg
Number of Main Contacts NO3
Number of Main Contacts NC1
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
Rated Operational VoltageMain circuit: 400 V AC; 220 V DC
Rated Frequency (f)Control circuit: 50 Hz, 60 Hz, 400 Hz and DC; main circuit: 50 Hz, 60 Hz and DC
Rated Operational Current AC-1 (I e )Normally open: 40 A; normally closed: 30 A
Rated Operational Current AC-3 (I e )Normally open: 22 A at 230 V single-phase or 400 V three-phase
Rated Operational Current AC-7a (I e )(NO) 40 A
Rated Operational Current AC-7b (I e )Normally open: 22 A at 230 V single-phase or 400 V three-phase
Rated Operational Power AC-1 (P e )(230 V) Single Phase, NC 6.9 kW
Rated Operational Power AC-3 (P e )(230 V) Single Phase, NO 3.7 kW
Rated Operational Power AC-7a (P e )(230 V) Single Phase, NC 6.9 kW
Rated Operational Power AC-7b (P e )(230 V) Single Phase, NO 3.7 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
Rated Insulation Voltage (U i )500 V
Rated Impulse Withstand Voltage (U imp )6 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (U c )230 V
Power Lossat Rated Operating Conditions AC-1 per Pole 3 W
Published component typeInstallation Contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Ambient operating temperature−25 to +55 °C
Degree of protectionIP20
Width in modular spacings3

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.