Illustration technique. Representative component image; exact configuration and appearance may vary. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.
1SAM250000R1005 — Motor protection circuit-breaker
Électricité et commandesRéférence de la pièce: 1SAM250000R1005
ABB MS116-1.0 (1SAM250000R1005) is a three-pole motor protection circuit-breaker with screw terminals and an adjustable overload setting of 0.63–1.0 A. It has a rated operational current of 1 A, thermal overload and short-circuit protection, and phase-failure sensitivity. At 400 V AC its rated service short-circuit breaking capacity is 50 kA.
Vous recherchez ABB 1SAM250000R1005 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | ABB |
|---|---|
| Référence de la pièce | 1SAM250000R1005 |
| Catégorie | Électricité et commandes |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-1.0 valid for production date from week 34/2014 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.225 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 50 kA at 230 V AC; 50 kA at 400 V AC; 50 kA at 440 V AC; 30 kA at 500 V AC; 30 kA at 690 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 100 kA at 230, 400, 440, 500 and 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 12.5 A |
| Setting Range | 0.63–1.0 A |
| Rated Operational Power AC-3 (P e ) | 0.25 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 0.25 kW |
| Rated Operational Voltage | Main circuit: 690 V AC |
| Rated Operational Current (I e ) | 1 A |
| Rated Operational Current AC-3 (I e ) | 1 A |
| Rated Operational Current AC-3e (I e ) | 1 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.6 ... 1.6 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 1 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Integrated Auxiliary Switch | No |
Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.
Questions sur le produit
Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.
Obtenir un devis pour cette pièce