1SAM250000R1008Photographie du produit non fournie

Référence de catalogue. Disponibilité, spécifications exactes et fourniture d’origine ou adaptable confirmées dans le devis.

ABB

1SAM250000R1008 — Motor protection circuit-breaker

Électricité et commandes

Référence de la pièce: 1SAM250000R1008

ABB 1SAM250000R1008 is the MS116-4.0 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 2.5–4.0 A overload setting, trip class 10A, screw terminals and a rotary ON/OFF handle. Designed for manual motor switching, it provides overload, short-circuit and phase-failure protection. Its rated service short-circuit breaking capacity is 50 kA at 400 V AC. Confirm motor and circuit requirements before selection.

Vous recherchez ABB 1SAM250000R1008 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAM250000R1008
CatégorieÉlectricité et commandes
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-4.0
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )230 V AC: 50 kA; 400 V AC: 50 kA; 440 V AC: 6 kA; 500 V AC: 6 kA; 690 V AC: 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )230 V AC: 75 kA; 400 V AC: 75 kA; 440 V AC: 18 kA; 500 V AC: 15 kA; 690 V AC: 3 kA
Rated Instantaneous Short-Circuit Current Setting (I i )50 A
Setting Range2.5–4.0 A
Rated Operational Power AC-3 (P e )400 V, three-phase: 1.5 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 1.5 kW
Rated Operational VoltageMain circuit 690 V AC
Rated Operational Current (I e )4 A
Rated Operational Current AC-3 (I e )4 A
Rated Operational Current AC-3e (I e )4 A
Rated Frequency (f)Main circuit 50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 4 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Extended product typeMS116-4.0
Trip class10A

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.