1SAM250000R1009 — Motor protection circuit-breaker
Électricité et commandesRéférence de la pièce: 1SAM250000R1009
ABB 1SAM250000R1009 is the MS116-6.3 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 4.0–6.3 A thermal overload setting, trip class 10A and a 2.2 kW AC-3 rating at 400 V. It provides manual motor switching and protection against overload, short circuit and phase failure. Suitability depends on motor and circuit ratings.
Vous recherchez ABB 1SAM250000R1009 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | ABB |
|---|---|
| Référence de la pièce | 1SAM250000R1009 |
| Catégorie | Électricité et commandes |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-6.3 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 50 kA at 230 V AC and 400 V AC; 6 kA at 440 V AC and 500 V AC; 2 kA at 690 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 75 kA at 230 V AC and 400 V AC; 18 kA at 440 V AC; 15 kA at 500 V AC; 3 kA at 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 78.8 A |
| Setting Range | 4.0–6.3 A |
| Rated Operational Power AC-3 (P e ) | 2.2 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 2.2 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 6.3 A |
| Rated Operational Current AC-3 (I e ) | 6.3 A |
| Rated Operational Current AC-3e (I e ) | 6.3 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.8 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 6.3 A |
| Degree of Protection | Housing IP20 |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10A |
| Mounting on DIN Rail | TH35-7.5 or TH35-15, 35 mm DIN rail |