1SAM250000R1011 — Motor protection circuit-breaker
Électricité et commandesRéférence de la pièce: 1SAM250000R1011
ABB MS116-16 (1SAM250000R1011) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 10–16 A overload setting. It provides thermal overload and electromagnetic short-circuit protection, phase-loss sensitivity and manual switching. The device has screw terminals, a trip class of 10A and a rated operational current of 16 A.
Vous recherchez ABB 1SAM250000R1011 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | ABB |
|---|---|
| Référence de la pièce | 1SAM250000R1011 |
| Catégorie | Électricité et commandes |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-16 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 16 kA at 230 V AC; 16 kA at 400 V AC; 6 kA at 440 V AC; 4 kA at 500 V AC; 2 kA at 690 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 16 kA at 230 V AC; 16 kA at 400 V AC; 15 kA at 440 V AC; 10 kA at 500 V AC; 3 kA at 690 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 240 A |
| Setting Range | 10–16 A |
| Rated Operational Power AC-3 (P e ) | 7.5 kW at 400 V AC, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 7.5 kW |
| Rated Operational Voltage | 690 V AC, main circuit |
| Rated Operational Current (I e ) | 16 A |
| Rated Operational Current AC-3 (I e ) | 16 A |
| Rated Operational Current AC-3e (I e ) | 16 A |
| Rated Frequency (f) | 50/60 Hz, main circuit |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.8 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 16 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10A |
| Mounting on DIN Rail | TH35-7.5 or TH35-15, 35 mm DIN rail |