Illustration technique — ABB 1SAM340000R1003 — 1SAM340000R1003 — Power circuit-breaker for trafo/generator/installation protection

Illustration technique. Representative component image; exact configuration and appearance may vary. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.

ABB

1SAM340000R1003 — Power circuit-breaker for trafo/generator/installation protection

Électricité et commandes

Référence de la pièce: 1SAM340000R1003

ABB 1SAM340000R1003 (MS132-0.4T) is a three-pole circuit breaker designed for primary-side protection of control transformers against overload and short circuit. It has a 0.25–0.40 A adjustable current range, screw terminals and a lockable rotary handle. Its rated service breaking capacity is 100 kA at 400 V AC. Confirm suitability for the transformer and installation before selection.

Vous recherchez ABB 1SAM340000R1003 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAM340000R1003
CatégorieÉlectricité et commandes
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-0.4T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.215 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(400 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )8 A
Setting Range0.25 ... 0.40 A
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )0.4 A
Rated Frequency (f)Main circuit 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.5 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 0.4 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 and TH35-7.5, 35 mm mounting rail according to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10
Actuator TypeLockable rotary handle, ON / OFF / TRIP indication

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.