Illustration technique — ABB 1SAM340000R1014 — 1SAM340000R1014 — Power circuit-breaker for trafo/generator/installation protection

Illustration technique. Representative component image; exact configuration and appearance may vary. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.

ABB

1SAM340000R1014 — Power circuit-breaker for trafo/generator/installation protection

Électricité et commandes

Référence de la pièce: 1SAM340000R1014

ABB MS132-25T (1SAM340000R1014) is a three-pole circuit breaker designed for primary-side protection of control transformers. It provides overload and short-circuit protection, a 20–25 A adjustable overload setting, screw terminals and a lockable rotary handle with ON/OFF/TRIP indication.

Vous recherchez ABB 1SAM340000R1014 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAM340000R1014
CatégorieÉlectricité et commandes
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-25T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.05 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )50 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )500 A
Setting Range20–25 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )25 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.2 ... 1.9 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 25 A
Degree of ProtectionHousing: IP20; main circuit terminals: IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 or TH35-7.5, 35 mm rail according to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.