Illustration technique — ABB 1SAM451000R1016 — 1SAM451000R1016 — Motor protection circuit-breaker

Illustration technique. Published product/series reference; confirm the exact configuration and supplied appearance. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.

ABB

1SAM451000R1016 — Motor protection circuit-breaker

Électricité et commandes

Référence de la pièce: 1SAM451000R1016

ABB 1SAM451000R1016 is an MS165-54 three-pole manual motor starter and motor protection circuit breaker. It has a 40–54 A adjustable overload setting, trip class 10, screw terminals and a lockable rotary handle. The device provides overload, phase-failure and short-circuit protection and is rated 22 kW for three-phase AC-3 operation at 400 V. Verify motor current and installation fault level before selection.

Vous recherchez ABB 1SAM451000R1016 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAM451000R1016
CatégorieÉlectricité et commandes
Ex Operating InstructionsATEX - Operating instructions for MS165 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS165-54
Cut-off Current CharacteristicCut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165
Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.97 kg
Rated Service Short-Circuit Breaking Capacity (I cs )30 kA at 230 V AC; 30 kA at 400 V AC; 20 kA at 500 V AC; 6 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )50 kA at 230 V AC; 50 kA at 400 V AC; 20 kA at 500 V AC; 8 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )810 A
Setting Range40–54 A
Rated Operational Power AC-3 (P e )22 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 22 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )54 A
Rated Operational Current AC-3 (I e )54 A
Rated Operational Current AC-3e (I e )54 A
Rated Operational Current DC-5 (I e )54 A
Rated Frequency (f)Main Circuit 50 Hz
Operating Frequency (f sw )0 ... 415 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 8 kV
Rated Insulation Voltage (U i )1000 V
Power Lossat Rated Operating Conditions per Pole 3.84 ... 6.99 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 54 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.