ABB 1SAX111001R1104 is the E16DU-6.3 electronic overload relay for motor overload and phase-failure protection. It is self-supplied, with a 2.0–6.3 A current setting range, selectable 10E, 20E or 30E trip class, and manual or automatic reset. It has one normally closed trip contact and one normally open signal contact.

Vous recherchez ABB 1SAX111001R1104 ? Cette référence de catalogue est classée sous « relais ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce1SAX111001R1104
CatégorieÉlectricité et commandes
Time-Current Characteristic CurveTripping characteristic - Electronic overload relay E16DU, E45DU E80DU, E140DU, E200DU, E320DU, E500DU, E800DU from cold state. Valid for production date from week 49/07 (0497)
Product Net Width44.4 mm
Product Net Height74.6 mm
Product Net Depth / Length57 mm
Product Net Weight0.15 kg
Setting Range2.0–6.3 A
Rated Operational VoltageMain circuit: 690 V AC; auxiliary circuit: 600 V AC/DC
Rated Operational Current (I e )6.3 A
Rated Frequency (f)Auxiliary Circuit 50 Hz
Rated Impulse Withstand Voltage (U imp )Auxiliary Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (I th )Auxiliary Circuit NC 6 A
Rated Operational Current AC-15 (I e )(240 V) NC 3 A
Rated Operational Current DC-13 (I e )(125 V) NC 0.55 A
Degree of ProtectionIP20
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 0.008 ... 0.083 W
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSAB600
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-10 AWG
Published component typeElectronic overload relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10E, 20E or 30E, selectable
ResetManual or automatic, selectable
External Power SupplyNot required; self-supplied

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.