Illustration technique — ABB 2CSA275103R1204 — 2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Illustration technique. Published product/series reference; confirm the exact configuration and supplied appearance. Images fournies à titre indicatif. L’apparence de la pièce livrée peut varier.

ABB

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device

Électricité et commandes

Référence de la pièce: 2CSA275103R1204

2CSA275103R1204 — Earth leakage circuit breaker with auxiliary device — ABB reference 2CSA275103R1204. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Vous recherchez ABB 2CSA275103R1204 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantABB
Référence de la pièce2CSA275103R1204
CatégorieÉlectricité et commandes
Type of Residual CurrentType A
Test Voltage (Ut)170 … 264 V
Dielectric Test Voltage2.5 kV
Rated Ultimate Short-Circuit Breaking Capacity (I cu )10 kA
Rated Residual Breaking Capacity (IΔm)6 kA
Rated Service Short-Circuit Breaking Capacity (I cs )7.5 kA
Power Supply ConnectionArbitrary
Number of Protected Poles1
Number of Poles1P+N
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Mounting Position of AccessoriesRight
Connecting CapacityBusbar 10 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Rated Operational Voltage230...240 V AC
Rated Insulation Voltage (U i )500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Input Voltage TypeAC
Rated Current (I n )20 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity10 kA
Rated Frequency (f)50 … 60 Hz
Power Loss4.2 W
Overvoltage CategoryIII
Ambient Air TemperatureOperation -25 ... 55 °C
Published component typeEarth leakage circuit breaker with auxiliary device
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.