C103TM050Photographie du produit non fournie

Référence de catalogue. Disponibilité, spécifications exactes et fourniture d’origine ou adaptable confirmées dans le devis.

Schneider Electric

C103TM050 — This TM50D is a 3 poles 3d thermal-magnetic trip unit used on ComPacT NSX 100/160 circuit breakers. This 50A rating thermal-magnetic trip unit is an optimum choice for all…

Électricité et commandes

Référence de la pièce: C103TM050

C103TM050 — This TM50D is a 3 poles 3d thermal-magnetic trip unit used on ComPacT NSX 100/160 circuit breakers. This 50A rating thermal-magnetic trip unit is an optimum choice for all… — Schneider Electric reference C103TM050. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Vous recherchez Schneider Electric C103TM050 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.

Disponibilité sur demande

Prix sur devis

Livraison incluseGarantie et serviceObtenir un devis pour cette pièce

Caractéristiques techniques

FabricantSchneider Electric
Référence de la pièceC103TM050
CatégorieÉlectricité et commandes
RangeComPacT
Range of productComPacT NSX100...250 ComPacT NSX100...250 DC
Product or component typeTrip unit
Range compatibilityComPacT NSX100 ComPacT NSX160 ComPacT NSX100 DC
Poles description3P
Protected poles description3D
Trip unit protection functionsLI
Protection typeL : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating50 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz 750 V DC
Network frequency50/60 Hz
Circuit breaker mounting modeFixed
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s at 1.5 x In 15 s at 6 x Ir
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range500 A
Earth-leakage protectionWithout
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.

Questions sur le produit

Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.

Obtenir un devis pour cette pièce

Bienvenue chez vous.

Choisissez votre langue et votre destination de livraison. Le prix final et la livraison seront confirmés dans votre devis.