Référence de catalogue. Disponibilité, spécifications exactes et fourniture d’origine ou adaptable confirmées dans le devis.
C104TM100 — This TM100D is a 4 poles 4d thermal-magnetic trip unit used on ComPacT NSX 100/160/250 circuit breakers. This 100A rating thermal-magnetic trip unit is an optimum choice for…
Électricité et commandesRéférence de la pièce: C104TM100
C104TM100 — This TM100D is a 4 poles 4d thermal-magnetic trip unit used on ComPacT NSX 100/160/250 circuit breakers. This 100A rating thermal-magnetic trip unit is an optimum choice for… — Schneider Electric reference C104TM100. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Vous recherchez Schneider Electric C104TM100 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | Schneider Electric |
|---|---|
| Référence de la pièce | C104TM100 |
| Catégorie | Électricité et commandes |
| Range | ComPacT |
| Range of product | ComPacT NSX100...250 |
| Product or component type | Trip unit |
| Range compatibility | ComPacT NSX100 ComPacT NSX160 ComPacT NSX250 |
| Poles description | 4P |
| Protected poles description | 4D |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network frequency | 50/60 Hz |
| Circuit breaker mounting mode | Fixed |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | 1 x Ir (4D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| Earth-leakage protection | Without |
| Reference status | Published part reference; specification and fitment require confirmation |