Image représentative du type de composant, pas une photo de cette marque ou référence exacte. Confirmez les spécifications ; la pièce livrée peut avoir un aspect différent.
LV429035 — This TM32D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 32A rating thermal-magnetic trip unit is an optimum choice for all…
Électricité et commandesRéférence de la pièce: LV429035
LV429035 — This TM32D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 32A rating thermal-magnetic trip unit is an optimum choice for all… — Schneider Electric reference LV429035. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Vous recherchez Schneider Electric LV429035 ? Cette référence de catalogue est classée sous « Électricité et commandes ». Envoyez la référence et les informations sur votre équipement pour vérifier les spécifications et la disponibilité, et obtenir un devis avec livraison incluse.
Disponibilité sur demande
Caractéristiques techniques
| Fabricant | Schneider Electric |
|---|---|
| Référence de la pièce | LV429035 |
| Catégorie | Électricité et commandes |
| Range | ComPact |
| Range of Product | ComPact NSX100...250 DC ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 32 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network Frequency | 50/60 Hz |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s 1.5 x In 15 s 6 x Ir |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 400 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Les informations du catalogue peuvent comporter des erreurs ou être obsolètes. Les spécifications complètes et les données vérifiées sont disponibles sur demande. Confirmez avec nous la référence et la compatibilité avec votre équipement avant de commander.
Questions sur le produit
Les résultats de recherche pour cette pièce ne sont pas encore disponibles en français. Contactez notre équipe pour obtenir de l’aide.
Obtenir un devis pour cette pièce