Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.
1SAE231111R0640 — Installation Contactor
contattoreCodice ricambio: 1SAE231111R0640
ABB 1SAE231111R0640, type ESB25-40N-06, is a four-pole installation contactor with four normally open main contacts and a 230–240 V AC/DC control coil. Its rated operational current is 25 A for AC-1 and 9 A for AC-3 at 230 V single-phase or 400 V three-phase. The unit is 36 mm wide and occupies two modular spaces. Confirm the load and control-circuit requirements before selection.
Cerchi ABB 1SAE231111R0640? Questa referenza di catalogo è classificata come «contattore». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAE231111R0640 |
| Categoria | Elettricità e controllo |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.235 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4 |
| Rated Operational Voltage | Main circuit: 220 V DC; 400 V AC |
| Rated Frequency (f) | Control circuit: DC, 50 Hz, 60 Hz or 400 Hz; main circuit: DC, 50 Hz or 60 Hz |
| Rated Operational Current AC-1 (I e ) | 25 A, normally open |
| Rated Operational Current AC-3 (I e ) | 9 A at 230 V single-phase or 400 V three-phase, normally open |
| Rated Operational Current AC-7a (I e ) | (NO) 25 A |
| Rated Operational Current AC-7b (I e ) | (230 V) Single Phase, NO 9 A |
| Rated Operational Power AC-1 (P e ) | (230 V) Single Phase, NO 5.8 kW |
| Rated Operational Power AC-3 (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase |
| Rated Operational Power AC-7a (P e ) | (230 V) Single Phase, NO 5.8 kW |
| Rated Operational Power AC-7b (P e ) | (230 V) Single Phase, NO 1.3 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 230–240 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Degree of Protection | IP20 |
| Operating Ambient Temperature | −25 to +55 °C |
| Width in Modular Spacings | 2 |