Illustrazione tecnica — ABB 1SAM250000R1003 — 1SAM250000R1003 — Motor protection circuit-breaker

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM250000R1003 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM250000R1003

ABB MS116-0.4 (1SAM250000R1003) is a three-pole manual motor starter with an adjustable 0.25–0.40 A overload setting. It provides overload and short-circuit protection, phase-loss sensitivity and manual motor switching. Its rated AC-3 operational power is 0.09 kW at 400 V.

Cerchi ABB 1SAM250000R1003? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM250000R1003
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-0.40 valid for productiondate from week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.225 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 230 V AC; 50 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )5 A
Setting Range0.25–0.40 A
Rated Operational Power AC-3 (P e )0.09 kW at 400 V
Rated Operational Power AC-3e (P e )(400 V) Three Phase 0.09 kW
Rated Operational Voltage690 V AC, main circuit
Rated Operational Current (I e )0.4 A
Rated Operational Current AC-3 (I e )0.4 A
Rated Operational Current AC-3e (I e )0.4 A
Rated Frequency (f)50/60 Hz, main circuit
Rated Impulse Withstand Voltage (U imp )6 kV, main circuit
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.7 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 0.4 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting35 mm DIN rail TH35-7.5 or TH35-15

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.