Illustrazione tecnica — ABB 1SAM250000R1004 — 1SAM250000R1004 — Motor protection circuit-breaker

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM250000R1004 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM250000R1004

ABB 1SAM250000R1004 is the MS116-0.63 manual motor starter and motor protection circuit-breaker. This three-pole device provides manual switching and protection against overload, short circuit and phase failure. Its overload setting range is 0.40–0.63 A, with a rated operational current of 0.63 A. It has a rotary handle, screw terminals and a 45 mm width.

Cerchi ABB 1SAM250000R1004? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM250000R1004
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-0.63 valid for production date from week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.225 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 230 V AC; 50 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )7.9 A
Setting Range0.40–0.63 A
Rated Operational Power AC-3 (P e )(400 V) Three Phase 0.18 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 0.18 kW
Rated Operational VoltageMain circuit 690 V AC
Rated Operational Current (I e )0.63 A
Rated Operational Current AC-3 (I e )0.63 A
Rated Operational Current AC-3e (I e )0.63 A
Rated Frequency (f)Main circuit 50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.7 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 0.63 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Actuator TypeRotary handle
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.