Illustrazione tecnica — ABB 1SAM250000R1009 — 1SAM250000R1009 — Motor protection circuit-breaker

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM250000R1009 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM250000R1009

ABB 1SAM250000R1009 is the MS116-6.3 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 4.0–6.3 A thermal overload setting, trip class 10A and a 2.2 kW AC-3 rating at 400 V. It provides manual motor switching and protection against overload, short circuit and phase failure. Suitability depends on motor and circuit ratings.

Cerchi ABB 1SAM250000R1009? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM250000R1009
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-6.3
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 230 V AC and 400 V AC; 6 kA at 440 V AC and 500 V AC; 2 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )75 kA at 230 V AC and 400 V AC; 18 kA at 440 V AC; 15 kA at 500 V AC; 3 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )78.8 A
Setting Range4.0–6.3 A
Rated Operational Power AC-3 (P e )2.2 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 2.2 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )6.3 A
Rated Operational Current AC-3 (I e )6.3 A
Rated Operational Current AC-3e (I e )6.3 A
Rated Frequency (f)50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 6.3 A
Degree of ProtectionHousing IP20
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm DIN rail

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.