1SAM250000R1012 — Motor protection circuit-breaker
Elettricità e controlloCodice ricambio: 1SAM250000R1012
ABB MS116-12 (1SAM250000R1012) is a three-pole motor protection circuit breaker with thermomagnetic protection and an adjustable 8–12 A thermal overload setting. It has screw terminals, a 690 V rated operational voltage and a 5.5 kW AC-3 rating at 400 V. Verify motor current and installation requirements before selection.
Cerchi ABB 1SAM250000R1012? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAM250000R1012 |
| Categoria | Elettricità e controllo |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-12 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | (230 V AC) 25 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 50 kA at 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 180 A |
| Setting Range | 8–12 A |
| Rated Operational Power AC-3 (P e ) | 5.5 kW at 400 V |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 5.5 kW |
| Rated Operational Voltage | 690 V AC |
| Rated Operational Current (I e ) | 12 A |
| Rated Operational Current AC-3 (I e ) | 12 A |
| Rated Operational Current AC-3e (I e ) | 12 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.0 ... 2.3 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 12 A |
| Degree of Protection | IP20 housing |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |