1SAM250000R1013 — Motor protection circuit-breaker
Elettricità e controlloCodice ricambio: 1SAM250000R1013
ABB MS116-20, part number 1SAM250000R1013, is a three-pole manual motor starter with an adjustable 16–20 A overload setting. It provides overload, short-circuit and phase-loss protection, with a rotary manual control and trip class 10A. The device is suitable for single-phase and three-phase applications, subject to correct selection and connection.
Cerchi ABB 1SAM250000R1013? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAM250000R1013 |
| Categoria | Elettricità e controllo |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS116-20 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS116 |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 85.4 mm |
| Product Net Weight | 0.31 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 10 kA at 230 V AC and 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | 16 kA at 230 V AC and 400 V AC |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 300 A |
| Setting Range | 16–20 A |
| Rated Operational Power AC-3 (P e ) | 7.5 kW at 400 V, three-phase |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 7.5 kW |
| Rated Operational Voltage | Main circuit: 690 V AC |
| Rated Operational Current (I e ) | 20 A |
| Rated Operational Current AC-3 (I e ) | 20 A |
| Rated Operational Current AC-3e (I e ) | 20 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.5 ... 2.3 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 20 A |
| Degree of Protection | Housing IP20 |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Tightening Torque | Main Circuit 2 N·m |
| Wire Stripping Length | Main Circuit 10 mm |
| Mounting Position | 1 ... 6 |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10A |