ABB

1SAM250000R1015 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM250000R1015

ABB 1SAM250000R1015 is the MS116-32 manual motor starter and motor protection circuit-breaker. It has a 25–32 A adjustable overload setting, three poles and screw terminals. It provides manual motor switching and protection against overload, short circuits and phase failure. Rated service breaking capacity is 10 kA at 400 V AC.

Cerchi ABB 1SAM250000R1015? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM250000R1015
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS116-32
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS116
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length85.4 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )10 kA at 230 V AC and 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )16 kA at 230 V AC and 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )480 A
Setting Range25–32 A
Rated Operational Power AC-3 (P e )15 kW at 400 V AC, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 15 kW
Rated Operational Voltage690 V AC, main circuit
Rated Operational Current (I e )32 A
Rated Operational Current AC-3 (I e )32 A
Rated Operational Current AC-3e (I e )32 A
Rated Frequency (f)50/60 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.9 ... 3.1 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 32 A
Degree of ProtectionIP20 housing; IP10 main circuit terminals
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10A
DIN rail mountingTH35-7.5 or TH35-15

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.