Illustrazione tecnica — ABB 1SAM340000R1014 — 1SAM340000R1014 — Power circuit-breaker for trafo/generator/installation protection

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM340000R1014 — Power circuit-breaker for trafo/generator/installation protection

Elettricità e controllo

Codice ricambio: 1SAM340000R1014

ABB MS132-25T (1SAM340000R1014) is a three-pole circuit breaker designed for primary-side protection of control transformers. It provides overload and short-circuit protection, a 20–25 A adjustable overload setting, screw terminals and a lockable rotary handle with ON/OFF/TRIP indication.

Cerchi ABB 1SAM340000R1014? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM340000R1014
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-25T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.05 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )50 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )50 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )500 A
Setting Range20–25 A
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )25 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.2 ... 1.9 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 25 A
Degree of ProtectionHousing: IP20; main circuit terminals: IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Tightening TorqueMain Circuit 2 N·m
Wire Stripping LengthMain Circuit 10 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 or TH35-7.5, 35 mm rail according to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.