1SAM350000R1004 — Motor protection circuit-breaker
Elettricità e controlloCodice ricambio: 1SAM350000R1004
ABB 1SAM350000R1004 is the MS132-0.63 three-pole manual motor starter and motor protection circuit-breaker. It has an adjustable 0.40–0.63 A overload setting, screw terminals and a rotary handle. It provides manual motor switching and protection against overload, short circuit and phase failure. It is suitable for single- and three-phase applications, subject to circuit and motor selection requirements.
Cerchi ABB 1SAM350000R1004? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAM350000R1004 |
| Categoria | Elettricità e controllo |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-0.63 valid for production date from week 34/2014 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.215 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (230 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 7.9 A |
| Setting Range | 0.40–0.63 A |
| Rated Operational Power AC-3 (P e ) | (400 V) Three Phase 0.18 kW |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 0.18 kW |
| Rated Operational Voltage | Main circuit: 690 V AC; 250 V DC |
| Rated Operational Current (I e ) | 0.63 A |
| Rated Operational Current AC-3 (I e ) | 0.63 A |
| Rated Operational Current AC-3e (I e ) | 0.63 A |
| Rated Operational Current DC-5 (I e ) | 0.63 A |
| Rated Frequency (f) | Main circuit: 50 Hz and 60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.7 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 0.63 A |
| Degree of Protection | Housing IP20 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10 |
| Mounting | TH35-7.5 or TH35-15 DIN rail |