Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.
1SAM350000R1005 — Motor protection circuit-breaker
Elettricità e controlloCodice ricambio: 1SAM350000R1005
ABB 1SAM350000R1005 is the MS132-1.0 manual motor starter and motor protection circuit-breaker. It has a 0.63–1.0 A adjustable overload range, three poles and screw terminals. It provides overload, short-circuit and phase-failure protection, with a lockable rotary handle and ON/OFF/TRIP indication. ABB describes it as suitable for single- and three-phase applications; confirm circuit and motor ratings before selection.
Cerchi ABB 1SAM350000R1005? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAM350000R1005 |
| Categoria | Elettricità e controllo |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-1.0 valid for production date form week 34/2014 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.215 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | 100 kA at 230 V AC; 100 kA at 400 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (230 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 12.5 A |
| Setting Range | 0.63–1.0 A |
| Rated Operational Power AC-3 (P e ) | 0.25 kW at 400 V AC, three phase |
| Rated Operational Power AC-3e (P e ) | 0.25 kW at 400 V AC, three phase |
| Rated Operational Voltage | Main circuit: 690 V AC; 250 V DC |
| Rated Operational Current (I e ) | 1 A |
| Rated Operational Current AC-3 (I e ) | 1 A |
| Rated Operational Current AC-3e (I e ) | 1 A |
| Rated Operational Current DC-5 (I e ) | 1 A |
| Rated Frequency (f) | Main circuit: 50 / 60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.6 ... 1.6 W |
| Number of Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 1 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Terminal Type | Screw terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10 |
Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.
Domande sul prodotto
Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.
Richiedi un preventivo per questo ricambio