Illustrazione tecnica — ABB 1SAM350000R1005 — 1SAM350000R1005 — Motor protection circuit-breaker

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM350000R1005 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM350000R1005

ABB 1SAM350000R1005 is the MS132-1.0 manual motor starter and motor protection circuit-breaker. It has a 0.63–1.0 A adjustable overload range, three poles and screw terminals. It provides overload, short-circuit and phase-failure protection, with a lockable rotary handle and ON/OFF/TRIP indication. ABB describes it as suitable for single- and three-phase applications; confirm circuit and motor ratings before selection.

Cerchi ABB 1SAM350000R1005? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM350000R1005
CategoriaElettricità e controllo
Ex Operating InstructionsATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS132-1.0 valid for production date form week 34/2014
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.215 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC; 100 kA at 400 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )12.5 A
Setting Range0.63–1.0 A
Rated Operational Power AC-3 (P e )0.25 kW at 400 V AC, three phase
Rated Operational Power AC-3e (P e )0.25 kW at 400 V AC, three phase
Rated Operational VoltageMain circuit: 690 V AC; 250 V DC
Rated Operational Current (I e )1 A
Rated Operational Current AC-3 (I e )1 A
Rated Operational Current AC-3e (I e )1 A
Rated Operational Current DC-5 (I e )1 A
Rated Frequency (f)Main circuit: 50 / 60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.6 ... 1.6 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 1 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.