1SAM350000R1012 — Motor protection circuit-breaker
Elettricità e controlloCodice ricambio: 1SAM350000R1012
ABB MS132-12 (1SAM350000R1012) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 8–12 A overload setting. It provides manual switching and protection against overload, short circuit and phase failure. Rated operational power is 5.5 kW at 400 V three-phase under AC-3; the device has screw terminals and a lockable rotary handle.
Cerchi ABB 1SAM350000R1012? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAM350000R1012 |
| Categoria | Elettricità e controllo |
| Ex Operating Instructions | ATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas |
| Time-Current Characteristic Curve | Tripping characteristic - Manual Motor Starter MS132-12.0 |
| Cut-off Current Characteristic | Cut-off Current Characteristic @ 400V -Manual Motor Starter MS132 |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 86.55 mm |
| Product Net Weight | 0.31 kg |
| Rated Service Short-Circuit Breaking Capacity (I cs ) | (230 V AC) 100 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (I cu ) | (230 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (I i ) | 180 A |
| Setting Range | 8.0 ... 12 A |
| Rated Operational Power AC-3 (P e ) | (400 V) Three Phase 5.5 kW |
| Rated Operational Power AC-3e (P e ) | (400 V) Three Phase 5.5 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (I e ) | 12 A |
| Rated Operational Current AC-3 (I e ) | 12 A |
| Rated Operational Current AC-3e (I e ) | 12 A |
| Rated Operational Current DC-5 (I e ) | 12 A |
| Rated Frequency (f) | Main circuit: 50/60 Hz |
| Operating Frequency (f sw ) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.0 ... 2.3 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (I th ) | Main Circuit 12 A |
| Degree of Protection | Housing IP20 |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Published component type | Motor protection circuit-breaker |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip class | 10 |
| Rated service short-circuit breaking capacity at 400 V AC | 100 kA |
| Mounting on DIN rail | TH35-7.5 or TH35-15, 35 mm rail |
| Contact position indication | ON / OFF / TRIP |
| Main circuit terminal protection | IP10 |