Illustrazione tecnica — ABB 1SAM350000R1012 — 1SAM350000R1012 — Motor protection circuit-breaker

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SAM350000R1012 — Motor protection circuit-breaker

Elettricità e controllo

Codice ricambio: 1SAM350000R1012

ABB MS132-12 (1SAM350000R1012) is a three-pole manual motor starter and motor protection circuit-breaker with an adjustable 8–12 A overload setting. It provides manual switching and protection against overload, short circuit and phase failure. Rated operational power is 5.5 kW at 400 V three-phase under AC-3; the device has screw terminals and a lockable rotary handle.

Cerchi ABB 1SAM350000R1012? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM350000R1012
CategoriaElettricità e controllo
Ex Operating InstructionsATEX - Operating instructions for Manual Motor Starters MS132 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS132-12.0
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.55 mm
Product Net Weight0.31 kg
Rated Service Short-Circuit Breaking Capacity (I cs )(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )180 A
Setting Range8.0 ... 12 A
Rated Operational Power AC-3 (P e )(400 V) Three Phase 5.5 kW
Rated Operational Power AC-3e (P e )(400 V) Three Phase 5.5 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )12 A
Rated Operational Current AC-3 (I e )12 A
Rated Operational Current AC-3e (I e )12 A
Rated Operational Current DC-5 (I e )12 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 1.0 ... 2.3 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 12 A
Degree of ProtectionHousing IP20
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10
Rated service short-circuit breaking capacity at 400 V AC100 kA
Mounting on DIN railTH35-7.5 or TH35-15, 35 mm rail
Contact position indicationON / OFF / TRIP
Main circuit terminal protectionIP10

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.