ABB MO132-10 (1SAM360000R1010) is a three-pole, magnetic-only manual motor starter rated at 10 A. It provides manual switching and short-circuit protection with a disconnect function. An appropriate separate thermal or electronic overload relay is required for motor overload protection.

Cerchi ABB 1SAM360000R1010? Questa referenza di catalogo è classificata come «relè». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SAM360000R1010
CategoriaElettricità e controllo
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter Magnetic Only MO132-4 ... MO132-32
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V -Manual Motor Starter MS132
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I i )125 A
Rated Operational Power AC-3 (P e )4 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 4 kW
Rated Operational VoltageMain circuit: 690 V AC
Rated Operational Current (I e )10 A
Rated Operational Current AC-3 (I e )10 A
Rated Operational Current AC-3e (I e )10 A
Rated Frequency (f)Main circuit: 50/60 Hz
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 2.2 W
Number of Poles3P
Conventional Free-air Thermal Current (I th )Main Circuit 10 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail
Overload protectionSeparate appropriate thermal or electronic overload relay required for motor overload protection
Protection typeMagnetic short-circuit protection

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.