Riferimento di catalogo. Disponibilità, specifiche esatte e fornitura originale o alternativa sono confermate nel preventivo.
1SAZ211201R2047 — Thermal overload relay
relèCodice ricambio: 1SAZ211201R2047
ABB 1SAZ211201R2047, type TA25DU-19M, is a thermal overload relay with a 13–19 A adjustable current range and class 10A trip characteristic. It provides motor overload and phase-failure protection, selectable manual or automatic reset, and one normally closed trip contact and one normally open signal contact. It connects directly to suitable block contactors; verify the contactor and application before ordering.
Cerchi ABB 1SAZ211201R2047? Questa referenza di catalogo è classificata come «relè». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAZ211201R2047 |
| Categoria | Elettricità e controllo |
| Time-Current Characteristic Curve | Tripping characteristic - Thermal overload relay TA25DU-19, TA25DU-19 V1000 |
| Product Net Width | 44 mm |
| Product Net Height | 80 mm |
| Product Net Depth / Length | 94 mm |
| Product Net Weight | 0.17 kg |
| Rated Operational Voltage | Main circuit: 690 V AC; 440 V DC |
| Rated Operational Current (I e ) | 19 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Number of Poles | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 5 A |
| Rated Operational Current AC-15 (I e ) | (120 V) NC 3 A |
| Degree of Protection | Housing IP20; main circuit terminals IP10 |
| Connecting Capacity Auxiliary Circuit | Flexible 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 0.75 ... 4 mm² |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.3 W |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 12 in·lb |
| Ambient Air Temperature | Operation: -25 to +55 °C; compensated operation: -25 to +55 °C; storage: -40 to +70 °C |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Published component type | Thermal overload relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Overload current setting range | 13–19 A |
| Trip class | 10A |
| Reset mode | Selectable manual or automatic |
| Protection functions | Motor overload and phase failure |
Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.
Domande sul prodotto
Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.
Richiedi un preventivo per questo ricambio