Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.
1SAZ431201R1004 — Thermal overload relay
relèCodice ricambio: 1SAZ431201R1004
ABB 1SAZ431201R1004 is the TF140DU-142 three-pole thermal overload relay, with an adjustable 110–142 A setting range and trip class 10A. It provides motor overload and phase-failure protection, with selectable manual or automatic reset, temperature compensation, trip indication, STOP and TEST functions, and one normally open and one normally closed auxiliary contact.
Cerchi ABB 1SAZ431201R1004? Questa referenza di catalogo è classificata come «relè». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SAZ431201R1004 |
| Categoria | Elettricità e controllo |
| Time-Current Characteristic Curve | Tripping characteristic - Thermal overload relay TF140DU-142/TF140DU-142-V1000 |
| Product Net Width | 89 mm |
| Product Net Height | 140 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Weight | 0.82 kg |
| Setting Range | 110–142 A |
| Rated Operational Voltage | Auxiliary Circuit 440 V DC |
| Rated Operational Current (I e ) | 142 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Number of Poles | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 10 A |
| Rated Operational Current AC-15 (I e ) | (120 V) NC 3 A |
| Rated Operational Current DC-13 (I e ) | (125 V) NC 0.25 A |
| Degree of Protection | Housing: IP20; main circuit terminals: IP10 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 16 ... 70 mm² |
| Tightening Torque | Auxiliary Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Mounting Position | any |
| Power Loss | at Rated Operating Conditions per Pole 2.3 W |
| Maximum Operating Voltage UL/CSA | Main circuit: 600 V AC |
| Contact Rating UL/CSA | (NC:) B600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 6-2/0 AWG |
| Published component type | Thermal overload relay |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Trip Class | 10A |
| Reset Method | Selectable manual or automatic |
| Main Circuit Rated Operational Voltage | 690 V AC; 440 V DC |
Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.
Domande sul prodotto
Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.
Richiedi un preventivo per questo ricambio