1SBL103001R8110 — Block Contactor
contattoreCodice ricambio: 1SBL103001R8110
ABB 1SBL103001R8110 (ASL09-30-10-81) is a three-pole block contactor with a 24 V DC control coil, three normally open main contacts and one built-in normally open auxiliary contact. Its AC-3 rating is 9 A at 380–400 V and 4 kW at 400 V. It uses screw terminals and is intended for motor and power-circuit control.
Cerchi ABB 1SBL103001R8110? Questa referenza di catalogo è classificata come «contattore». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | ABB |
|---|---|
| Codice ricambio | 1SBL103001R8110 |
| Categoria | Elettricità e controllo |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.28 kg |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 22 A |
| Rated Operational Current AC-3 (I e ) | 9 A at 380–400 V and 60 °C; 9 A at 415 V and 60 °C; 8 A at 440–500 V and 60 °C; 5 A at 690 V and 60 °C |
| Rated Operational Current AC-15 (I e ) | (500 V) NC 2 |
| Rated Operational Current DC-13 (I e ) | (24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (P e ) | 4 kW at 400 V; 2.2 kW at 220–240 V |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U c ) | 24 V DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Published component type | Block Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Extended product type | ASL09-30-10-81 |
| Terminal Type | Screw terminals |
| Mounting on DIN Rail | TH35-7.5 or TH35-15; 35 mm rail |
| Degree of Protection | IP20 at main, auxiliary and coil terminals |
Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.