Illustrazione tecnica — ABB 1SFL447002R1211 — 1SFL447002R1211 — Block Contactor

Illustrazione tecnica. Representative component image; exact configuration and appearance may vary. Immagini solo di riferimento. L’aspetto del componente fornito può variare.

ABB

1SFL447002R1211 — Block Contactor

contattore

Codice ricambio: 1SFL447002R1211

1SFL447002R1211 — Block Contactor — ABB reference 1SFL447002R1211. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Cerchi ABB 1SFL447002R1211? Questa referenza di catalogo è classificata come «contattore». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreABB
Codice ricambio1SFL447002R1211
CategoriaElettricità e controllo
Product Net Width90 mm
Product Net Depth / Length126 mm
Product Net Height150 mm
Product Net Weight1.3 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A
Rated Operational Current AC-1 (I e )(690 V) 40 °C 200 A
Rated Operational Current AC-3 (I e )(415 V) 55 °C 140 A
Rated Operational Current AC-3e (I e )(415 V) 60 °C 140 A
Rated Operational Current DC-1 (I e )(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (I e )(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (I e )(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (P e )(415 V) 75 kW
Rated Operational Power AC-3e (P e )(415 V) 75 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
Rated Insulation Voltage (U i )acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (U imp )Main Circuit 8 kV
Published component typeBlock Contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.