Schneider Electric

A9DE3632 — Residual current breaker with overcurrent protection (RCBO)

Elettricità e controllo

Codice ricambio: A9DE3632

A9DE3632 — Residual current breaker with overcurrent protection (RCBO) — Schneider Electric reference A9DE3632. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Cerchi Schneider Electric A9DE3632? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreSchneider Electric
Codice ricambioA9DE3632
CategoriaElettricità e controllo
RangeActi9
product nameActi9 iCV40
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Poles description1P + N
Number of protected poles1
[In] rated current32 A
Network frequency50/60 Hz
[Ue] rated operational voltage230 V AC 50/60 Hz
Residual current tripping technologyVoltage independent
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Local signallingON/OFF indication Fault indication
Mounting modeClip-on
Mounting supportDIN rail
Connection pitch9 mm between phase and neutral
Height85 mm
Width36 mm
Depth73 mm
Product weight210 g
Connections - terminalsTunnel type terminals top or bottom 1…16 mm² rigid Tunnel type terminals top or bottom 1…10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
Published component typeResidual current breaker with overcurrent protection (RCBO)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.

Domande sul prodotto

Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.

Richiedi un preventivo per questo ricambio

Sentiti a casa.

Scegli la lingua e la destinazione di consegna. Il prezzo finale e la spedizione saranno confermati nel preventivo.