Immagine di riferimento del componente: Published product/series reference; confirm the exact configuration and supplied appearance.

Immagine rappresentativa del tipo di componente, non una foto di questo marchio o codice esatto. Confermare le specifiche; il pezzo fornito può avere un aspetto diverso.

Schneider Electric

GV4AE11 — TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the…

Gestione cavi e trasferimento di energia

Codice ricambio: GV4AE11

GV4AE11 — TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the… — Schneider Electric reference GV4AE11. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.

Cerchi Schneider Electric GV4AE11? Questa referenza di catalogo è classificata come «Gestione cavi e trasferimento di energia». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.

Disponibilità su richiesta

Prezzo su preventivo

Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambio

Specifiche tecniche

ProduttoreSchneider Electric
Codice ricambioGV4AE11
CategoriaGestione cavi e trasferimento di energia
RangeTeSys
Product or Component TypeAuxiliary contact
Range compatibilityTeSys TeSys GV4 TeSys TeSys BV4
[Ue] rated operational voltage<= 690 V
[Ith] conventional free air thermal current5 A IEC 60947-5-1 5 A CSA C22.2 No 14 5 A UL 508
Mounting ModeInternal mounting
[Ui] rated insulation voltage690 V IEC 60947-1
[Ie] rated operational current5 A <= 690 V AC-12 IEC 60947-5-1 5 A <= 48 V AC-15 IEC 60947-5-1 4 A 110/127 V AC-15 IEC 60947-5-1 3 A 220/240 V AC-15 IEC 60947-5-1 2.5 A 380...440 V AC-15 IEC 60947-5-1 0.11 A 660/690 V AC-15 IEC 60947-5-1 5 A <= 24 V DC-12 IEC 60947-5-1 2.5 A 48 V DC-12 IEC 60947-5-1 0.6 A 110/127 V DC-12 IEC 60947-5-1 0.3 A 250 V DC-12 IEC 60947-5-1 2.5 A <= 24 V DC-12 IEC 60947-5-1 1.2 A 48 V DC-12 IEC 60947-5-1 0.35 A 110/127 V DC-12 IEC 60947-5-1 0.05 A 250 V DC-12 IEC 60947-5-1 1 A <= 24 V DC-12 IEC 60947-5-1 0.2 A 48 V DC-12 IEC 60947-5-1 0.05 A 110/127 V DC-12 IEC 60947-5-1 0.03 A 250 V DC-12 IEC 60947-5-1
Rated power in VA120 VA AC-12 24 V IEC 60947-5-1 240 VA AC-12 48 V IEC 60947-5-1 635 VA AC-12 110/127 V IEC 60947-5-1 1200 VA AC-12 230/240 V IEC 60947-5-1 2200 VA AC-12 380/440 V IEC 60947-5-1 3450 VA AC-12 660/690 V IEC 60947-5-1
Rated power in WDC-12 120 W 24 V IEC 60947-5-1 DC-12 120 W 48 V IEC 60947-5-1 DC-12 66 W 110 V IEC 60947-5-1 DC-12 75 W 250 V IEC 60947-5-1
Associated fuse rating5 A gG at 690 V conforming to IEC 60947-5-1
Minimum switching current2 mA
Minimum switching voltage17 V
Connections - terminalsSpring terminals 1 0.0008…0.002 in² (0.5…1.5 mm²) - cable stiffness: flexible without cable end
Wire stripping length0.3 in (8 mm)
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request

Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.