Immagine rappresentativa del tipo di componente, non una foto di questo marchio o codice esatto. Confermare le specifiche; il pezzo fornito può avere un aspetto diverso.
LV429034 — This TM40D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 40A rating thermal-magnetic trip unit is an optimum choice for all…
Elettricità e controlloCodice ricambio: LV429034
LV429034 — This TM40D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 40A rating thermal-magnetic trip unit is an optimum choice for all… — Schneider Electric reference LV429034. Request a quotation including shipping to your destination. Send equipment details and certificate requirements so we can confirm the exact specification, fitment, availability and warranty terms before ordering.
Cerchi Schneider Electric LV429034? Questa referenza di catalogo è classificata come «Elettricità e controllo». Invia il codice articolo e i dati della macchina per verificare specifiche e disponibilità e ricevere un preventivo con spedizione inclusa.
Disponibilità su richiesta
Prezzo su preventivo
Spedizione inclusaGaranzia e assistenzaRichiedi un preventivo per questo ricambioSpecifiche tecniche
| Produttore | Schneider Electric |
|---|---|
| Codice ricambio | LV429034 |
| Categoria | Elettricità e controllo |
| Range | ComPact |
| Range of Product | ComPact NSX100...250 ComPact NSX100...250 DC |
| Product or Component Type | Trip unit |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 40 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network Frequency | 50/60 Hz |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s 1.5 x In 15 s 6 x Ir |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 500 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
Le informazioni del catalogo possono contenere errori o non essere aggiornate. Le specifiche complete e i dati verificati sono disponibili su richiesta. Confermate con noi il codice e la compatibilità con la macchina prima di ordinare.
Domande sul prodotto
Le informazioni ricercate su questo ricambio non sono ancora disponibili in italiano. Contatta il nostro team per assistenza.
Richiedi un preventivo per questo ricambio