技術図 — ABB 1SAE232111R0140 — 1SAE232111R0140 — Installation Contactor

技術図. Representative component image; exact configuration and appearance may vary. 画像は参考用です。納入される部品の外観は異なる場合があります。

ABB

1SAE232111R0140 — Installation Contactor

電磁接触器

部品番号: 1SAE232111R0140

ABB 1SAE232111R0140 (EN25-40N-01) is a four-pole installation contactor with four normally open main contacts and a 24 V AC/DC control circuit. It is rated 25 A for AC-1 duty and has On, Off and Auto operating positions. The main circuit and load ratings should be checked against the intended application.

ABB 1SAE232111R0140をお探しですか。このカタログ参照品は「電磁接触器」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。

在庫状況はお問い合わせください

価格はお見積もりにて

送料込み保証・サービスこの部品の見積もりを依頼

技術仕様

メーカーABB
部品番号1SAE232111R0140
カテゴリー電装・制御部品
Product Net Width36 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.25 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
Rated Operational VoltageMain circuit: 220 V DC; 400 V AC
Rated Frequency (f)Control circuit: 50, 60 or 400 Hz, or DC; main circuit: 50 or 60 Hz, or DC
Rated Operational Current AC-1 (I e )(NO) 25 A
Rated Operational Current AC-3 (I e )9 A, normally open, at 230 V single-phase or 400 V three-phase
Rated Operational Current AC-7a (I e )(NO) 25 A
Rated Operational Current AC-7b (I e )9 A, normally open, at 230 V single-phase or 400 V three-phase
Rated Operational Power AC-1 (P e )5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open
Rated Operational Power AC-3 (P e )1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open
Rated Operational Power AC-7a (P e )5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open
Rated Operational Power AC-7b (P e )1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (U i )500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (U c )24 V AC/DC
Power Lossat Rated Operating Conditions AC-1 per Pole 2 W
Published component typeInstallation Contactor
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Degree of ProtectionIP20
Operating Ambient Temperature-25 to +55 °C
Manual operating positionsOn, Off, Auto
Width in modular spacings2

カタログ情報には誤りや古い情報が含まれる場合があります。完全な仕様と確認済みの詳細情報はお問い合わせください。ご注文前に部品番号とお使いの機械への適合を当社にご確認ください。

製品に関するご質問

この部品に関する調査情報は、まだ日本語ではご用意できていません。担当チームにお問い合わせください。

この部品の見積もりを依頼

ご利用環境に合わせて設定。

言語と配送先を選択してください。最終価格と配送条件はお見積もりで確定します。