ABB 1SAE232111R0140 (EN25-40N-01) is a four-pole installation contactor with four normally open main contacts and a 24 V AC/DC control circuit. It is rated 25 A for AC-1 duty and has On, Off and Auto operating positions. The main circuit and load ratings should be checked against the intended application.
ABB 1SAE232111R0140をお探しですか。このカタログ参照品は「電磁接触器」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。
在庫状況はお問い合わせください
技術仕様
| メーカー | ABB |
|---|---|
| 部品番号 | 1SAE232111R0140 |
| カテゴリー | 電装・制御部品 |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.25 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main circuit: 220 V DC; 400 V AC |
| Rated Frequency (f) | Control circuit: 50, 60 or 400 Hz, or DC; main circuit: 50 or 60 Hz, or DC |
| Rated Operational Current AC-1 (I e ) | (NO) 25 A |
| Rated Operational Current AC-3 (I e ) | 9 A, normally open, at 230 V single-phase or 400 V three-phase |
| Rated Operational Current AC-7a (I e ) | (NO) 25 A |
| Rated Operational Current AC-7b (I e ) | 9 A, normally open, at 230 V single-phase or 400 V three-phase |
| Rated Operational Power AC-1 (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-3 (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7a (P e ) | 5.8 kW at 230 V single-phase; 17.3 kW at 400 V three-phase, normally open |
| Rated Operational Power AC-7b (P e ) | 1.3 kW at 230 V single-phase; 4 kW at 400 V three-phase, normally open |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U i ) | 500 V |
| Rated Impulse Withstand Voltage (U imp ) | 4 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U c ) | 24 V AC/DC |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2 W |
| Published component type | Installation Contactor |
| Reference status | Published part reference; specification and fitment require confirmation |
| Availability | On request |
| Degree of Protection | IP20 |
| Operating Ambient Temperature | -25 to +55 °C |
| Manual operating positions | On, Off, Auto |
| Width in modular spacings | 2 |