技術図 — ABB 1SAM340000R1010 — 1SAM340000R1010 — Power circuit-breaker for trafo/generator/installation protection

技術図. Representative component image; exact configuration and appearance may vary. 画像は参考用です。納入される部品の外観は異なる場合があります。

ABB

1SAM340000R1010 — Power circuit-breaker for trafo/generator/installation protection

電装・制御部品

部品番号: 1SAM340000R1010

ABB 1SAM340000R1010 is the MS132-10T, a three-pole circuit breaker designed for primary-side control transformer protection. It provides adjustable overload protection from 6.3 to 10 A, a fixed 200 A instantaneous short-circuit setting and manual disconnect operation. The unit has screw terminals and a lockable rotary handle with ON/OFF/TRIP indication.

ABB 1SAM340000R1010をお探しですか。このカタログ参照品は「電装・制御部品」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。

在庫状況はお問い合わせください

価格はお見積もりにて

送料込み保証・サービスこの部品の見積もりを依頼

技術仕様

メーカーABB
部品番号1SAM340000R1010
カテゴリー電装・制御部品
Time-Current Characteristic CurveTripping characteristic - Circuit Breaker for Transformer Protection MS132-10T
Cut-off Current CharacteristicCut-off Current Characteristic @ 400V - Circuit Breaker for Transformer Protection MS132-T / MS132-KT
Product Net Width45 mm
Product Net Height97.8 mm
Product Net Depth / Length86.05 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA at 230 V AC and 400 V AC; 30 kA at 440 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )100 kA at 400 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )200 A
Setting Range6.3–10 A
Rated Operational Voltage690 V AC, main circuit
Rated Operational Current (I e )10 A
Rated Frequency (f)50/60 Hz, main circuit
Operating Frequency (f sw )0 ... 400 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.7 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 10 A
Degree of ProtectionHousing IP20; main circuit screw terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 or TH35-15, 35 mm rail to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Published component typePower circuit-breaker for trafo/generator/installation protection
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Overload Trip Class10

カタログ情報には誤りや古い情報が含まれる場合があります。完全な仕様と確認済みの詳細情報はお問い合わせください。ご注文前に部品番号とお使いの機械への適合を当社にご確認ください。

製品に関するご質問

この部品に関する調査情報は、まだ日本語ではご用意できていません。担当チームにお問い合わせください。

この部品の見積もりを依頼

ご利用環境に合わせて設定。

言語と配送先を選択してください。最終価格と配送条件はお見積もりで確定します。