技術図 — ABB 1SAM451000R1016 — 1SAM451000R1016 — Motor protection circuit-breaker

技術図. Published product/series reference; confirm the exact configuration and supplied appearance. 画像は参考用です。納入される部品の外観は異なる場合があります。

ABB

1SAM451000R1016 — Motor protection circuit-breaker

電装・制御部品

部品番号: 1SAM451000R1016

ABB 1SAM451000R1016 is an MS165-54 three-pole manual motor starter and motor protection circuit breaker. It has a 40–54 A adjustable overload setting, trip class 10, screw terminals and a lockable rotary handle. The device provides overload, phase-failure and short-circuit protection and is rated 22 kW for three-phase AC-3 operation at 400 V. Verify motor current and installation fault level before selection.

ABB 1SAM451000R1016をお探しですか。このカタログ参照品は「電装・制御部品」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。

在庫状況はお問い合わせください

価格はお見積もりにて

送料込み保証・サービスこの部品の見積もりを依頼

技術仕様

メーカーABB
部品番号1SAM451000R1016
カテゴリー電装・制御部品
Ex Operating InstructionsATEX - Operating instructions for MS165 for potentially explosive areas
Time-Current Characteristic CurveTripping characteristic - Manual Motor Starter MS165-54
Cut-off Current CharacteristicCut-off Current Characteristic @ 400/690V -Manual Motor Starter MS165/MO165
Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.97 kg
Rated Service Short-Circuit Breaking Capacity (I cs )30 kA at 230 V AC; 30 kA at 400 V AC; 20 kA at 500 V AC; 6 kA at 690 V AC
Rated Ultimate Short-Circuit Breaking Capacity (I cu )50 kA at 230 V AC; 50 kA at 400 V AC; 20 kA at 500 V AC; 8 kA at 690 V AC
Rated Instantaneous Short-Circuit Current Setting (I i )810 A
Setting Range40–54 A
Rated Operational Power AC-3 (P e )22 kW at 400 V, three-phase
Rated Operational Power AC-3e (P e )(400 V) Three Phase 22 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (I e )54 A
Rated Operational Current AC-3 (I e )54 A
Rated Operational Current AC-3e (I e )54 A
Rated Operational Current DC-5 (I e )54 A
Rated Frequency (f)Main Circuit 50 Hz
Operating Frequency (f sw )0 ... 415 Hz
Rated Impulse Withstand Voltage (U imp )Main Circuit 8 kV
Rated Insulation Voltage (U i )1000 V
Power Lossat Rated Operating Conditions per Pole 3.84 ... 6.99 W
Number of Poles3
Conventional Free-air Thermal Current (I th )Main Circuit 54 A
Degree of ProtectionHousing IP20; main circuit terminals IP10
Terminal TypeScrew terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Published component typeMotor protection circuit-breaker
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip class10

カタログ情報には誤りや古い情報が含まれる場合があります。完全な仕様と確認済みの詳細情報はお問い合わせください。ご注文前に部品番号とお使いの機械への適合を当社にご確認ください。

製品に関するご質問

この部品に関する調査情報は、まだ日本語ではご用意できていません。担当チームにお問い合わせください。

この部品の見積もりを依頼

ご利用環境に合わせて設定。

言語と配送先を選択してください。最終価格と配送条件はお見積もりで確定します。