部品番号: 1SAZ421301R1005

ABB 1SAZ421301R1005, type TA200DU-175-V1000, is a three-pole thermal overload relay for motor overload and phase-loss protection. It has a 130–175 A adjustable current range, class 10A trip characteristic, one normally closed and one normally open auxiliary contact, and selectable manual or automatic reset.

ABB 1SAZ421301R1005をお探しですか。このカタログ参照品は「リレー」に分類されています。部品番号と機械の情報をお送りください。仕様と供給状況を確認し、送料込みのお見積もりをご案内します。

在庫状況はお問い合わせください

価格はお見積もりにて

送料込み保証・サービスこの部品の見積もりを依頼

技術仕様

メーカーABB
部品番号1SAZ421301R1005
カテゴリー電装・制御部品
Ex Operating InstructionsOperating instructions - Thermal overload relay TA200DU V1000
Time-Current Characteristic CurveTripping characteristic - Thermal overload relay TA200DU-175, TA200DU-175 V1000
Product Net Width104 mm
Product Net Height151 mm
Product Net Depth / Length126 mm
Product Net Weight0.77 kg
Setting Range130–175 A
Rated Operational VoltageAuxiliary Circuit 440 V DC
Rated Operational Current (I e )175 A
Rated Frequency (f)Auxiliary Circuit 50 Hz
Rated Impulse Withstand Voltage (U imp )Auxiliary Circuit 6 kV
Rated Insulation Voltage (U i )690 V
Number of Poles3
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (I th )Auxiliary Circuit NC 10 A
Rated Operational Current AC-15 (I e )(120 V) NC 3 A
Rated Operational Current DC-13 (I e )(125 V) NC 0.25 A
Degree of ProtectionHousing IP20; main circuit terminals IP00
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitHole Diameter > 10 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.3 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 3.8 ... 6.9 W
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NO:) B600
Published component typeThermal overload relay
Reference statusPublished part reference; specification and fitment require confirmation
AvailabilityOn request
Trip Class10A
Auxiliary Contacts1 normally open and 1 normally closed
Reset MethodSelectable manual or automatic